Chemical-free Upright type Lyophilizer - LYCF(Organic solvent only)

-120℃ Chemical free Lyophilizer Exclusively for Organic Solvent
  • All-in-one product that pre-freezing is possible using mini-tray
  • Drying Acceleration system using the compressor waste heat - option
Features
  • Chemical-free lyophilizer can collect the organic solvent with freezing point of -115℃~-95℃ such as ethanol, methanol, acetone, nucleic acid, iso-octane, etc. easily with the cold trap having powerful cooling force under -120℃.
  • In case of freeze drying sample containing organic solvent of which freezing point is under -100℃ user should equip expensive cryogenic freezer separately or should use liquid nitrogen for pre-freezing that has given the user difficulties due to not only its cost but inconvenience especially danger and sample contamination possibilities of liquid nitrogen. In addition, in case of the general -86℃ class freezer, the user suffers difficulty because the sample does not freeze properly or the experiment often fails because the sample is melted on the way to move it to the drying chamber.
    Since this model can freeze at the temperature under -120℃ (built in pre-freezing) using 5-layer stainless steel mini-tray, it is fast and convenient and is the product suitable to perform the experiment economically.
  • If you select the large volume flask and portable stoppering device, stoppering, sterilization, sample temperature detection, etc. are possible
Controller & Others
controller
  • 7” TFT LCD Touch Screen
  • AI (Artificial Intelligence) Advisor
  • Internet of Thing (IoT)
Validation Service(Option)
controller
  • Installation Qualification (IQ)
  • Operational Qualification (OQ)
  • Test & Calibration
Special Feature
controller
  • Applied with patented built-in pre-freezing structure design, it performs one-stop operation from pre-freezing to lyophilization in one lyophilizer.
Application
  • Lyophilizer exclusively for organic solvent is used in the area drying the matters, which the freezing point of the solvent diluted is between -115℃ and -95℃ such as ethanol, methanol, nucleic acid, iso-octane, etc, directly without other pre-treatment process.
    Especially, our chemical-free lyophilizer is the product used by the user most who experienced the experiment failure by the frequent failure of the vacuum pump and the organic solvent dispersion due to insufficient pre-freezing out of the users of -86℃ class lyophilizer.
Specification
Model No. LYOPHILIZER (Chemical free)
LYCF-12015 LYCF-12008 LYCF-12004
Main Body Cold Trap Temp -120℃ or less -120℃ or less -120℃ or less
Capacity (Total) 15L 8L 4L
Dimensions, mm(Exterior) W850 x D850 x H991 W850 x D850 x H991 W800 x D650 x H980
Trap Size, mm Ø340 x L380 Ø310 x L260 Ø310 x L140
Controller 7" TFT LCD Touch Screen, AI (Artificial Intelligence) Advisor, Internet of Things(IoT), DPMS(Intake air differential pressure monitoring), USB Backup Port(Default 16GB), External output(Ethernet, RS-485, Modbus), External transmission of analog data (temperature, vacuum), Real-time ambient temperature detection (monitoring/alarm), Real-time voltage detection (monitoring/alarm), cumulative running time monitoring (preliminary freezing/freezing drying/total running time)
Pump Protection System Auto/Manual start-up controller, Display cold trap, Temperature & vacuum pressure (2000mTorr ~ 0mTorr), printer set
Defrost Auto/Manual
Safety Device Compressor overload prevention circuit, vacuum pump overload prevention circuit, evaporator abnormality alarm, voltage booster, real-time low voltage alarm,
Real-time ambient temperature monitoring and alarm, defrost completion alarm and control, vacuum leakage alarm and control, temperature sensor abnormality alarm, vacuum sensor abnormality alarm
Electrical 220V 1Phase 50/60Hz
Weight 225kg 216kg 148kg
Certification ISO 9001:2015 / KS Q ISO 9001:2015
Composition Vacuum Pump, Chemical trap, Oil mist trap
The lyophilizer exclusively for organic solvent is equipped with powerful freezing cycle that can freeze and collect the organic solvent

Below are the pictures of 99.9% ethanol lyophilized and collected using LYCF series lyophilizer (pictures taken during our institute’s test)
 

ethanol
The function of FSD(Flask Sublimation Device Pack) pack is to induce the waste heat generated from the compressor and to enhance the lyophilization speed by accelerating the sublimation. It can be turned on/off by the user’s needs

When FSD pack is activated, the drying speed is increased approximately by 25% (Test result of our institute)

25% speed increase when the drying acceleration system is activated
Freezing Points
Product Application
Applied T type Manifold (24 ports)

Vacuum valve, glass adapter (45°),
A type cap, flask (300ml)

Applied D type Acrylic Manifold Chamber (8 ports)

Vacuum valve, glass adapter (45°),
Diverse configurations (cap, flask),
Flask stoppering device

Applied D type Acrylic Manifold Chamber (8 ports)

Vacuum valve, glass adapter (45°), Mini tray,
diverse configurations (cap, flask),
Flask stoppering device

Applied D type Stainless Manifold Chamber (8 ports)

Vacuum valve, glass adapter (45°),
Diverse configurations (cap, flask),
Flask stoppering device

Applied Stoppering Chamber (8 ports)

Vacuum valve, glass adapter (45°),
Flask stoppering device,
Diverse configurations (cap, flask)

Applied MPA Chamber (8 ports)

Vacuum valve, glass adapter (45°), Mini
tray, FSD Pack, diverse configurations
(cap, flask), Flask stoppering device